Skip to content

Public-source contaminant table

What Contaminants Are in Tampa, FL Tap Water? (2026)

Tampa's official UCMR5 and CCR records show posted PFOA/PFOS detections around the 0.004 µg/L EPA PFOA/PFOS MCL, HAA5 below the federal MCL, and lead/copper below action levels; older UCMR rows remain archival-context checks.

Rows tracked

13

Above-limit flags

4

Last reviewed

May 22, 2026

Next source review

June 22, 2026

Utility context

City of Tampa Water Department

PWSID

FL6290327

Source water

Surface water (Hillsborough River / Tampa Bypass)

Disinfectant

Chloramine

Research rows

Contaminants and water-quality flags

Source type and confidence are shown so each claim keeps its evidence trail attached.

ContaminantDetected valueYearLimit / guidelineComparisonEvidence
Chlorate
City of Tampa · ZIP 33602
630 µg/LUCMR 3No MCLHealth goal: 210 µg/L (EPA Lifetime HA)EXCEEDS HA ~3xepa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026
Chromium-6
City of Tampa · ZIP 33602
0.26 µg/LUCMR 3No federal MCL; CA 10 µg/LHealth goal: 0.02 µg/L (CA PHG)Below CA MCL; above CA PHGepa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026
PFOA
City of Tampa · ZIP 33602
ND-0.0046 µg/LUCMR 5 (2023)0.004 µg/L (EPA PFOA/PFOS MCL)Health goal: 0One posted 2023 UCMR result above the PFOA/PFOS MCL; later Morris Bridge set shows NDtampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
PFOS
City of Tampa · ZIP 33602
0.0040-0.0069 µg/LUCMR 5 (2023)0.004 µg/L (EPA PFOA/PFOS MCL)Health goal: 0 (MCLG)Detected above the PFOA/PFOS MCL in posted 2023 UCMR samples; compliance uses running annual averagestampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
1,4-Dioxane
City of Tampa · ZIP 33602
0.17 µg/LUCMR 3No MCLHealth goal: 0.35 µg/L (EPA HA)49% of HAepa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026
Copper (90th pct)
City of Tampa · ZIP 33602
0.277 mg/LLCR 20231.3 mg/L (Action Level)Below AL; no sampling sites over the copper action leveltampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
HAA5
City of Tampa · ZIP 33602
26.12 µg/LCCR 202460 µg/LWithin limit (~44% of the 60 µg/L MCL)tampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
Lead (90th pct)
City of Tampa · ZIP 33602
1.81 ppbLCR 202315 ppb (AL)Health goal: 0Below AL; no sampling sites over the lead action leveltampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
Manganese
City of Tampa · ZIP 33602
4.7 µg/LUCMR 450 µg/L (secondary)Within limitepa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026
NDMA
City of Tampa · ZIP 33602
6.7 ng/LUCMR 2No MCLHealth goal: 10 ng/L (CA PHG)67% of PHG; probable carcinogenepa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026
PFBS
City of Tampa · ZIP 33602
0.0030-0.0064 µg/LUCMR 5 (2023-2025)No individual MCL; hazard-index component under 2024 ruleDetected in posted Tampa UCMR samples; hazard-index provisions are under EPA reconsiderationtampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
PFHxS
City of Tampa · ZIP 33602
ND-0.0041 µg/LUCMR 5 (2023)0.010 µg/L (EPA 2024 PFAS MCL; proposed for reconsideration)Detected below the 2024 PFHxS MCL in posted Tampa UCMR samples; EPA has proposed reconsiderationtampa.gov
Primary official source · Verified against official public source
Verified May 22, 2026 · Next review August 22, 2026
Strontium
City of Tampa · ZIP 33602
793 µg/LUCMR 3No MCLHealth goal: 1500 µg/L (EPA HRL)Elevated (53% of HRL)epa.gov
Directional official-source context · Directional claim; keep qualified until row-level source is rechecked
Verified May 22, 2026 · Next review June 22, 2026

How to read this table

Legal limit

EPA MCLs and action levels are compliance standards. They are not the same as stricter health goals.

Health guideline

Health-guideline context can be more conservative and should be labeled clearly.

Home-level certainty

Public utility data does not prove the exact contaminant level at one faucet.

Trust and source notes

Built from public water data, then translated for the home

BaseWater's contaminant pages use public utility reports, EPA-linked SDWIS or UCMR context, EWG health-guideline context, row-level official checks for high-stakes claims, and BaseWater source-quality labels. BaseWater pages separate legal compliance from stricter health-guideline context. They are not a medical diagnosis or a tap-level lab result for any individual home.

Last reviewed

May 22, 2026

Reviewed by

BaseWater local water-data review

Data snapshot

May 22, 2026

Sources used on this page

Turn Tampa water data into a home-specific next step

Use the free audit to connect public utility data, your ZIP, and what you notice at home before deciding whether a water test or whole-home system makes sense.